Alice Bean US Testing FE electronics - hybrids functionally tested after reception if they fail - ship back to Europe to fix except small wirebonding jobs Sensors - visually inspected fraction are probed at KSU Modules optical inspection after fluing fast acceptance test after bonding, pull bonds if needed do dead channel testing without using laser scan but with bias tests assure that bonding is proceeding smoothly by calibrating machines with pull tests daily - we don't think temperature cycling will be needed For all cases, if we can get away without temperature cycling we should At the start if you find "bad" modules set them aside and hope you don't have to repair although our Fermilab experiences say that 80% of our time was spent on repairs and non-optimal modules We need to have a strict go - nogo rule so that variations by grade will not have to be decided upon for rod assembly We would like to do the minimal tests necessary for completion as we are worried that repairs might dominate in the end